A Two-Vector Framework for MRI Knee Diagnostics: Fuzzy Risk Modeling, Digital Maturity, and Finite-Element Wear Assessment

Applied Sciences, 2026

Full text Open access: Gold Metadata (CSL-JSON)
DOI 10.3390/app16031554
Data confidence 85 high
How this score is calculated

It is built from checkable properties of the record itself: whether the article has a DOI, how many independent sources confirmed its data, whether the required fields are filled in, and how recent the latest confirmation is. Disagreement between sources and a missing identifier lower it. A value of 80 or above means the record was published without further checking; 60 to 79 means it is published at reduced confidence, with a manual check advisable. A record verified by an editor by hand is never pushed below 90 by a recalculation. This scores our data about the article, not the article itself.

Abstract

Knee disorders are a major indication for musculoskeletal imaging, yet MRI reliability remains constrained by signal nonuniformity, motion artefacts, protocol variability, and reader-dependent effects. This study presents an integrated two-vector framework that couples (i) a fuzzy diagnostic control-risk model with (ii) a quantitative digital-maturity assessment to strengthen MRI-based diagnosis of knee pathology. The vertical vector characterizes organizational readiness through a weighted fuzzy aggregation of six capability agents (technical, information and analytical, mathematical/model, metrological, human resources, and software support). The horizontal vector estimates producer’s and consumer’s risks as misclassification probabilities relative to an acceptance boundary, driven by measurement/interpretation uncertainty, variability of the decision threshold, and the ratio of instrumental to physiological dispersion. Simulation results indicate that error probabilities increase sharply when threshold uncertainty exceeds 20–25% and rise by approximately 15–20% as the standard-deviation ratio approaches unity. To connect diagnostic reliability with downstream mechanics, a FE analysis of the tibial insert in TKA under F=1150 N at 0° flexion predicts a peak contact pressure of 85.449 MPa and a maximum UHMWPE von Mises stress of 43.686 MPa, identifying wear-critical contact zones. Overall, the proposed framework provides interpretable quantitative targets for QA, protocol refinement, and resource allocation in radiology services undergoing digital transformation, and offers a reproducible pathway for linking imaging reliability to biomechanical risk.