Full-Scale Experimental Investigation of the Influence of Solar Radiation on the Thermal Behavior of Ventilated Façade Envelope Systems Under Hot Climate Conditions

2025

Full text Open access: Gold Metadata (CSL-JSON)
DOI 10.3390/buildings16010122
Data confidence 70 medium
How this score is calculated

It is built from checkable properties of the record itself: whether the article has a DOI, how many independent sources confirmed its data, whether the required fields are filled in, and how recent the latest confirmation is. Disagreement between sources and a missing identifier lower it. A value of 80 or above means the record was published without further checking; 60 to 79 means it is published at reduced confidence, with a manual check advisable. A record verified by an editor by hand is never pushed below 90 by a recalculation. This scores our data about the article, not the article itself.

Abstract

The article presents the results of a comprehensive full-scale investigation of the influence of solar radiation on the thermal behavior of the exterior envelope systems of two residential buildings of different heights—a 9-storey building in Turkestan and a 25-storey building in Shymkent. The façade systems of both buildings consist of a multilayer enclosure with a ventilated air cavity, 100 mm wide in the 9-storey building and 50 mm wide in the 25-storey building. The objective of the study was to determine the diurnal and vertical dynamics of temperature fields, analyze the thermal inertia of the materials, and assess the effect of façade geometry on heat-transfer performance. Thermographic measurements were carried out during key periods of the day (7:00, 10:00, 13:00, and 17:00), which enabled coverage of the full solar-insolation cycle. The results showed that the maximum temperatures of the external cladding reached 48–52 °C for the 9-storey building and 53–58 °C for the 25-storey building, with a vertical temperature gradient of 3–7 °C. The temperature of the interior surface varied within 28–32 °C and 29–34 °C, respectively, reflecting the influence of both solar heating and the width of the ventilation cavity on heat transfer. It was found that reducing the air-gap width intensifies natural convection and decreases the thermal inertia of the system, resulting in sharper temperature fluctuations. The study demonstrates that current design standards insufficiently account for the vertical non-uniformity of solar exposure and the aerodynamic processes within the ventilation channel. The findings can be used in the design of energy-efficient façade systems, in the refinement of regulatory methodologies, and in the development of heat-transfer models for high-rise buildings under conditions of increased solar radiation.