It is built from checkable properties of the record itself: whether the article has a DOI, how many independent sources confirmed its data, whether the required fields are filled in, and how recent the latest confirmation is. Disagreement between sources and a missing identifier lower it. A value of 80 or above means the record was published without further checking; 60 to 79 means it is published at reduced confidence, with a manual check advisable. A record verified by an editor by hand is never pushed below 90 by a recalculation. This scores our data about the article, not the article itself.

Abstract

The article deals with the problems of increasing the energy efficiency of vertical centrifugal pumps, and proposes a method for modifying the impellers. To increase the hydraulic efficiency, the option of replacing the traditional homogeneous paddle screen with a variable pitch heterogeneous screen was considered. To substantiate the expediency of applying the modification option, the theory of shockless flow entry into the impeller is presented and analyzed. To automate the calculations of the parameters of a heterogeneous lattice, a module was created in the PYTON environment. The results of an automated calculation of the parameters of a heterogeneous bladed lattice are presented, and the results of fluid flow simulation in two versions of the wheels are presented