It is built from checkable properties of the record itself: whether the article has a DOI, how many independent sources confirmed its data, whether the required fields are filled in, and how recent the latest confirmation is. Disagreement between sources and a missing identifier lower it. A value of 80 or above means the record was published without further checking; 60 to 79 means it is published at reduced confidence, with a manual check advisable. A record verified by an editor by hand is never pushed below 90 by a recalculation. This scores our data about the article, not the article itself.

Abstract

The paper presents the development of a triple probe consisting of three tungsten electrodes with a diameter of 1 mm, intended for applications on a plasma beam installation (PBI). The appropriate measuring equipment and electrical wiring diagram have been selected. The probe has successfully passed the commissioning tests, during which key factors were identified that are important for accurate interpretation of the results and integration into the diagnostic system of the PBI. Experimental measurements of plasma parameters using a triple probe showed comparable results with a single probe: the electron temperature was 7 eV, and the plasma concentration was – 10¹⁶ m⁻³. The experimental results obtained confirm the correct operation of the developed probe and its use in experiments due to the simplicity of data processing compared with other types of probes.