Development of a Digital System for Monitoring Emergency Conditions in 20 kV Distribution Networks

Energies, 2025

Full text Open access: Gold Metadata (CSL-JSON)
DOI 10.3390/en18040998
Data confidence 70 medium
How this score is calculated

It is built from checkable properties of the record itself: whether the article has a DOI, how many independent sources confirmed its data, whether the required fields are filled in, and how recent the latest confirmation is. Disagreement between sources and a missing identifier lower it. A value of 80 or above means the record was published without further checking; 60 to 79 means it is published at reduced confidence, with a manual check advisable. A record verified by an editor by hand is never pushed below 90 by a recalculation. This scores our data about the article, not the article itself.

Abstract

This article presents research on the possibilities of using information and communication technologies in monitoring systems for electrical networks with isolated neutral, aimed at improving and automating production functions in the energy sector. This aligns with the digitalization policy of Kazakhstan’s economy and is part of similar programs in the field of the electric power industry. This article explores an approach to organizing a digital monitoring system for emergency conditions, specifically single-phase ground faults in medium-voltage lines within the range of 6–35 kV, including the new voltage class of 20 kV. A version of such a system is proposed, based on a combination of a server, a wireless information network, and remote digital voltage measurement nodes. This wireless information and communication network is designed to detect the locations of single-phase ground faults (SPGF) using specialized zero-sequence voltage sensors installed at various points along the power transmission lines, along with wireless signal transmission channels to the dispatcher’s server. To ensure protection against industrial interference, based on the results of practical environment modeling, a transmission technology most resistant to external noise is selected. This article proposes the selection of equipment necessary for implementing wireless transmission technology and develops two versions of a digital voltmeter design based on low-power programmable microcontrollers. The proposed technical solutions require further experimental validation, and therefore, the authors plan to conduct additional research and practical experiments in the future.