CCQM-K170 - electrolytic conductivity at 0.5 S m-1 and 20 S m-1 - final report

2025

Full text Open access: Green Metadata (CSL-JSON)
DOI 10.1088/0026-1394/62/1a/08002
Data confidence 70 medium
How this score is calculated

It is built from checkable properties of the record itself: whether the article has a DOI, how many independent sources confirmed its data, whether the required fields are filled in, and how recent the latest confirmation is. Disagreement between sources and a missing identifier lower it. A value of 80 or above means the record was published without further checking; 60 to 79 means it is published at reduced confidence, with a manual check advisable. A record verified by an editor by hand is never pushed below 90 by a recalculation. This scores our data about the article, not the article itself.

Abstract

Main text The comparison CCQM-K170 is a subsequent key comparison of CCQM-K36.2016 and CCQM-K92. It aims to demonstrate the capabilities of the participating NMIs/DIs to measure the electrolytic conductivity of aqueous electrolyte solution in the electrolytic conductivity range around 0.5 S m-1 and 20 S m-1. The coordinating institute (NIM) prepared two potassium chloride solutions with the nominal electrolytic conductivity of 0.5 S m-1 and 20 S m-1, and verified their homogeneity and stability. Seventeen and twelve NMIs/DIs, respectively, reported their measurement results of 0.5 S m-1 and 20 S m-1 samples, respectively. The institutes used primary and secondary methods, and commercial instruments. Institutes using non-NMI CRMs as calibrants or CRMs from a participating NMI were excluded from KCRV calculation. The measurement results traceable to CRMs from the same non-participating NMI were combined into one result to be used for KCRV calculation. The results of institutes which have indicated technical problems were also excluded from KCRV calculation. The medians were agreed upon as the KCRVs for 0.5 S m-1 and 20 S m-1 solutions based on CCQM/2013-22 guidance document. Good agreement of the results was observed for the majority of participants. The results of this key comparison are considered representative for electrolytic conductivity measurement of aqueous electrolyte solution in the electrolytic conductivity range 0.15 S m-1 to 1.5 S m-1 and 5 S m-1 to 25 S m-1, respectively. This KC is intended as an updated support for the corresponding calibration and measurement capabilities (CMCs) entries in the key comparison data base of the BIPM. To reach the main text of this paper, click on Final Report . Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/ . The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).