AUTO-OSCILLATING MODE OF SCAN OF BUT END PROBE FOR DIAGNOSTICS OF BEAM-PLASMA DISCHARGE

2019

Full text Open access: Hybrid Metadata (CSL-JSON)
DOI 10.52676/1729-7885-2019-3-62-67
Data confidence 70 medium
How this score is calculated

It is built from checkable properties of the record itself: whether the article has a DOI, how many independent sources confirmed its data, whether the required fields are filled in, and how recent the latest confirmation is. Disagreement between sources and a missing identifier lower it. A value of 80 or above means the record was published without further checking; 60 to 79 means it is published at reduced confidence, with a manual check advisable. A record verified by an editor by hand is never pushed below 90 by a recalculation. This scores our data about the article, not the article itself.

Abstract

This paper presents the result of experimental testing of the methodology auto-oscillating mode probe, which is based on a previously developed mathematical model of the secondary emission instability of a plasma-surface contact. The method of auto-oscillating mode probe is designed to measure the plasma parameters of beam-plasma discharge (BPD) in the near-axial zone of a beam-plasma installation with a longitudinal magnetic field. A scheme had been developed for measuring the current and voltage of the probe using a low-inductance resistive voltage divider, the Rogowski coil with the current shunt, and current meter on the Hall effect. The ion current density in the near-axial zone of the SPR was determined.